苏州市米德曼智能科技有限公司
Suzhou Mideman Intelligent Technology Co., Ltd
DP6150(1500Vpk/70MHz)
DP6150(1500Vpk/70MHz)

Bandwidth(-3dB)70MHz

Range selection(Attenuation rate) 50X/500X



浏览次数:659
说明书: 产品说明书

1. Summary

l DP6000 Series High Voltage Differential Probe is designed with floating measurement function, with a maximum bandwidth up to 70MHz that can fulfill the need of most measuring system.

l DP6000 Series provides a wide measuring range for selection, and its differential measurement voltage range can meet the requirement of most measurement circuit.

l The users can enter the test mode to adjust the offset voltage of the probe and realize zero set.

l DP6000 Series provides a 5MHz bandwidth limit function. 5MHz frequency bandwidth can meet the measurement of the switching frequency of most FETs in switching power supplies, and can filter out higher frequency noise and interference.

l DP6000 Series has sound & light alarming function, and users can turn it off manually if needed.

l DP6000 Series is powered by USB connector, and it contains standard BNC output connector that can adapt oscilloscope of any brand. In which, require the oscilloscope input impedance set to 1MΩ. If set to 50Ω, the output attenuation is a half of the practical value.

The probe has good CMRR, with high input impedance and low capacitance at the input end, which can accurately and quickly measure differential voltage signals. It can be widely used in the research and development, debugging, or maintenance of switching power supplies, frequency converters, electronic ballasts, variable frequency household appliances, and other electrical power devices.  

 

Adapter CK-605
Alligator clip CK-261
Test hook CK-284
Insulated piston probe clip CK-281
Red & Black input extension cable CK-301
BNC Output cable CK-310/320
USB power supply cable CK-315

Model

DP6150

DP6350

DP6700

Bandwidth(-3dB)

70MHz

Rise time

≤5ns

Accuracy

±2%

Range selection

(Attenuation rate)

50X/500X

100X/1000X

100X/1000X

Maximum differential voltage(DC + Peak AC)

50X

±150V

100X

±350V

100X

±700V

500X

±1500V

1000X

±3500V

1000X

±7000V

Common mode voltage (Vp)

(DC + Peak AC)

±1500V

±3500V

±7000V

Maximum differential mode VS frequency curve

Figure 1

Figure 2

     Figure 3

Maximum input

voltage-to-earth (Vrms)

600V CATIII

1000V CATII

600V CATIII

1000V CATII

1000V CATIII

2300V CATI*

Input impedance

Single-ended to ground

5MΩ

5MΩ

20MΩ

Between inputs

10MΩ

10MΩ

40MΩ

Input capacitance

Single-ended to ground

<4pF

<4pF

<5pF

Between inputs

<2pF

<2pF

<2.5pF

CMRR

DC

>80dB

>80dB

>80dB

100kHz

>60dB

>60dB

>60dB

1MHz

>50dB

>50dB

>50dB

Noise(Vrms)

50X

<50mV  

100X

<100mV

100X

<220mV

500X

<300mV  

1000X

<600mV

1000X

<1.2V

Differential overvoltage detection level

50X

≥150V

100X

≥350V

100X

≥700V

500X

≥1500V

1000X

≥3500V

1000X

≥7000V

Propagation  time

Probe

50X

9ns

100X

9.3ns

100X

9.3ns

500X

7.5ns

1000X

7.4ns

1000X

7.2ns

BNC Line(1m)

About 5ns

Bandwidth limit filters (5MHz)

≥-3dB@5MHz

Overload indicator (red light)

Yes

Overload alarm

Yes(Can shut up manually)

Automatic save

Yes

Offset setting function

Yes( Set in test mode)

Terminate load

≥100kΩ

Power supply

USB 5V/1A adapter

Safety standard

IEC/EN 61010-031:2015 + AMD1:2018

EMC standard

EN61326-1:2013  EN61000-3-2:2006+A1:2009+A2:2009  EN61000-3-3:2013

*CAT I per IEC/EN 61010-031/A1:2008. No Rated Measurements Category per IEC/EN 61010-031:2015 + AMD1:2018.