苏州市米德曼智能科技有限公司
Suzhou Mideman Intelligent Technology Co., Ltd
P1300 1300Vpk/50MHz
P1300 1300Vpk/50MHz

Bandwidth(-3dB)  50MHz

Accuracy  ±2%



浏览次数:737
说明书: 产品说明书

1. Introduction

P1300 Series High Voltage Differential Probes are designed for the measurement of high voltage differential signal, to meet the demand for floating measurement. 


Electronic specification

Type

P1300

Bandwidth(-3dB)

50MHz

Rise time

≤7ns

Accuracy

±2%

Attenuation

50X/500X

Max differential measuring voltage

(DC + Peak AC)

50X

±130V

500X

±1300V

Common mode voltage (DC + Peak AC)

±1000V

Max differential voltage versus frequency curve

Reference Figure 1

Maximum input voltage-to-earth (Vrms)

600V CATIII 1000V CATII

Input impedance

Single-ended to ground

5MΩ

Between inputs

10MΩ

Input capacitor

Single-ended to ground

<4pF

Between inputs

<2pF

CMRR

DC

>80dB

100kHz

>60dB

1MHz

>50dB

Noise (Vrms)

50X

<50mV

500X

<300mV

Differential overvoltage detection level

50X

≥140V

500X

≥1400V

Propagation  time

Probe

about 10ns

BNC Line(1m)

about 5ns

Overload indicator (red light)

Yes

Terminate load

≥100kΩ

Power adaptor

DC 12V/1A